38 changes: 34 additions & 4 deletions docs/src/remap/remap.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -962,6 +962,14 @@ EMC_ABORT_INTERPRETER_ERROR_MDI = 10, // interpreter failed during MDI execution
EMC_ABORT_USER = 100 // user-defined abort codes start here
----

An OFF request calls `on_abort` once with reason 4 and an E-stop request once with reason 6, even when the machine is already off or in E-stop.
An E-stop reset, from E-stop or from off, calls it once with reason 5.
So when a GUI sends OFF or E-stop as it starts, `on_abort` runs before any program does.
If the machine was on, a second call with reason 7 follows the first, because the machine is no longer on.
Reason 7 also comes alone when motion switches itself off, for example when the `motion.enable` pin goes false.
An error that stops a program or MDI calls `on_abort` with 1, 3, 9 or 10; a G38.2 that ends without contact, for example, gives 3.
If the error leaves the machine on, as a G38.2 without contact does, no call with reason 7 follows; if it turns the machine off, as a joint amplifier fault does, a call with reason 7 follows.

[source,{ini}]
----
[RS274NGC]
Expand All @@ -984,22 +992,44 @@ M5 (spindle off)
G80 (cancel modal motion)
M9 (mist and coolant off)

o100 if [#1 eq 5]
(machine on)
o100 if [#1 eq 2]
(the HAL E-stop chain opened while the machine was on: a call with reason 7 follows)
o100 elseif [#1 eq 4]
(OFF requested: if the machine was on, a call with reason 7 follows)
o100 elseif [#1 eq 5]
(E-stop reset: the machine is still off)
o100 elseif [#1 eq 6]
(machine off)
(E-stop requested: if the machine was on, a call with reason 7 follows)
o100 elseif [#1 eq 7]
(estopped)
(what to run when the machine went off for any reason)
o100 elseif [#1 eq 8]
(msg, abort pressed)
o100 else
(an error stopped a program or MDI: if it also turned the machine off, a call with reason 7 follows)
(DEBUG, error parameter is [#1])
o100 endif

o<on_abort> endsub
m2
----

A procedure that only cleans up after a program or MDI was stopped can skip the state requests 4, 5 and 6.
If one of them stops a machine that was on, the call with reason 7 still comes:

[source,{ngc}]
----
o<on_abort> sub

o100 if [[#1 ge 4] and [#1 le 6]]
o<on_abort> return
o100 endif

G90 (absolute again, for example after a probing routine that used G91)

o<on_abort> endsub
m2
----

CAUTION: Never use an `M2` in a O-word subroutine, including this one.
It will cause hard-to-find errors.
For instance, using an `M2` in a subroutine will not end the subroutine properly and will leave the subroutine NGC file open,
Expand Down