This Python script is a general-purpose command-line interface (CLI) for interacting with JVL motors (tested with MAC400) that support Modbus TCP communication (directly or via a gateway). It allows reading and writing motor registers, setting operating modes, and monitoring register values.
This code was generated with the assistance of an AI model and is provided as-is. It has undergone some testing but may contain bugs or unexpected behavior. Always verify register addresses, command values, and motor behavior against the official JVL documentation for your specific motor model and firmware before performing any write operations or critical configurations. Incorrect use could lead to unexpected motor behavior, equipment damage, or safety hazards.
- Python 3.6+
pyModbusTCPlibrary: Install usingpip install pyModbusTCP
General Syntax:
python cli.py [global options] <command> [command-specific arguments]Global Options:
-i IP_ADDRESS,--ip-address IP_ADDRESS: The IP address of the JVL motor or the Modbus TCP gateway it's connected to. This is required for all commands exceptlist.-p PORT,--port PORT: The Modbus TCP port number. (Default: 502)-u UNIT_ID,--unit-id UNIT_ID: The Modbus Unit ID (slave ID) of the motor. (Default: 1)-v,--verbose: Enable detailed debug logging for troubleshooting.
Commands:
Lists all registers defined within the script, along with their JVL number, name, size, R/W status, and a brief description.
Syntax:
python cli.py list [filter_string]filter_string(optional): A case-insensitive string to filter the register list by name or JVL number.
Examples:
python cli.py list
python cli.py list MODE
python cli.py list ERR_STAT
python cli.py list 35Reads the current value(s) from one or more specified registers.
Syntax:
python cli.py -i <ip_address> read <register_name_or_num> [register_name_or_num_2 ...]Examples:
python cli.py -i 192.168.1.10 read MODE_REG
python cli.py -i 192.168.1.10 read P_IST V_IST_16 ERR_STAT
python cli.py -i 192.168.1.10 read 35 # Read register with JVL number 35 (ERR_STAT)The output will show the raw numerical value and, if a value_map is defined for the register (like for MODE_REG or ERR_STAT), an interpretation of that value (e.g., mode name or active error bits).
Writes a specified value to a single motor register.
Syntax:
python cli.py -i <ip_address> write <register_name_or_num> <value>Examples:
# Write raw value 1 to MODE_REG (JVL Reg 2) - equivalent to 'mode VELOCITY'
python cli.py -i 192.168.1.10 write MODE_REG 1Sets the motor to a predefined operating mode. This is a convenience wrapper around writing to MODE_REG.
Syntax:
python cli.py -i <ip_address> mode <MODE_NAME><MODE_NAME>: One of the modes defined in the script (e.g.,PASSIVE,VELOCITY,POSITION). Case-insensitive.
Example:
python cli.py -i 192.168.1.10 mode VELOCITY
python cli.py -i 192.168.1.10 mode PASSIVEContinuously polls and displays the values of specified registers. Press Ctrl+C to stop.
Syntax:
python cli.py -i <ip_address> watch <register_name_or_num> [register_name_or_num_2 ...] [--rate <seconds>]--rate <seconds>(optional): The polling interval in seconds. (Default: 1.0)
Examples:
python cli.py -i 192.168.1.10 watch P_IST V_IST_16 ERR_STAT
python cli.py -i 192.168.1.10 watch MODE_REG --rate 0.2Syntax:
python cli.py -i <ip_address> resetSyntax:
python cli.py -i <ip_address> saveThe script contains a dictionary (REGISTERS) defining known JVL registers. This includes:
- JVL Register Number: The numerical identifier from the manual.
- Name: A human-readable name.
- Encode/Decode Functions: Custom functions for scaling values (e.g., RPM, percentages) or interpreting bitfields.
- Read-Only Status: Indicates if a register can be written to.
- Description: A brief explanation of the register's purpose.
- Value Map: For registers like
MODE_REGorERR_STAT, this provides a mapping from raw values to their meanings (e.g., enum names or active bits).
You can extend this dictionary in the script to support more registers specific to your motor and application. Refer to the JVL MAC motor user manual (pages 406+ for MAC050-141, pages 416+ for MAC400-4500) for detailed register lists.
- Modbus Endianness: The script assumes JVL motors use Big Endian byte order for multi-word (32-bit) Modbus registers. This is typical but verify if you encounter unexpected 32-bit values.
- Scaling Factors: Many registers (like
V_SOLL,A_SOLL,U_BUS,DEGC) require scaling to convert between raw Modbus values and engineering units (RPM, V, °C). The script includes scaling factors based on the provided driver snippet; these may need adjustment for your specific motor model or if the internal scaling of the motor/gateway differs. - Command Register (CMD_REG): The address and values for special commands like
resetandsaveare critical. The current values (Reg 211, values 1 and 2) are placeholders and MUST be verified from your motor's specific documentation.
This script is provided for utility and educational purposes. The author(s) are not responsible for any damage to equipment or other issues that may arise from its use. Always test thoroughly in a non-critical environment first.